Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1103720150730040216
Journal of the Korean Society of Radiology
2015 Volume.73 No. 4 p.216 ~ p.224
Predicting Factors for Conversion from Fluoroscopy Guided Percutaneous Transthoracic Needle Biopsy to Cone-Beam CT Guided Percutaneous Transthoracic Needle Biopsy
Lee Kang-Ji

Han Young-Min
Jin Gong-Yong
Song Ji-Soo
Abstract
Purpose
To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB.

Materials and Methods
From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson ¥ö2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB.

Results
Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ¡¾ 1.57 cm, 3.40 ¡¾ 1.92 cm, 3.06 ¡¾ 1.81 cm, and 35.67 ¡¾ 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ¡¾ 1.30 cm, 2.20 ¡¾ 1.45 cm, 1.91 ¡¾ 1.99 cm, and 18.32 ¡¾ 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in CT attenuation value.

Conclusion
Low CT attenuation value and small short-axis diameter of the solid pulmonary lesion affect conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB.
KEYWORD
Percutaneous Transthoracic Needle Biopsy, Cone-Beam CT, Solid Pulmonary Lesion, Fluoroscopy, Predicting Factors