KMID : 1103720170760030198
|
|
Journal of the Korean Society of Radiology 2017 Volume.76 No. 3 p.198 ~ p.205
|
|
Intra- and Interobserver Reproducibility of Shear Wave Elastography for Evaluation of the Breast Lesions
|
|
Hong Min-Ji
Kim Hak-Hee
|
|
Abstract
|
|
|
Purpose: To evaluate reproducibility of shear wave elastography (SWE) for breast lesions within and between observers and compare the reproducibility of SWE features.
Materials and Methods: For intraobserver reproducibility, 225 masses with 208 patients were included; and two consecutive SWE images were acquired by each observer. For interobserver reproducibility, SWE images of the same mass were obtained by another observer before surgery in 40 patients. Intraclass correlation coefficients (ICC) were used to determine intra- and interobserver reproducibility.
Results: Intraobserver reliability for mean elasticity (Emean) and maximum elasticity (Emax) were excellent (ICC = 0.803, 0.799). ICC for SWE ratio and minimum elasticity (Emin) were fair to good (ICC = 0.703, 0.539). Emean showed excellent ICC regardless of histopathologic type and tumor size. Emax, SWE ratio and Emin represented excellent or fair to good reproducibility based on histopathologic type and tumor size. In interobserver study, ICC for Emean, Emax and SWE ratio were excellent. Emean, Emax and SWE ratio represented excellent ICC irrespective of histopathologic type. ICC for Emean was excellent regardless of tumor size. SWE ratio and Emax showed fair to good interobserver reproducibility based on tumor size. Emin represented poor interobserver reliability.
Conclusion: Emean in SWE was highly reproducible within and between observers.
|
|
KEYWORD
|
|
Breast, Ultrasonography, Elasticity Imaging Techniques, Breast Neoplasm
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|
|