KMID : 1103720200810061459
|
|
Journal of the Korean Society of Radiology 2020 Volume.81 No. 6 p.1459 ~ p.1465
|
|
Interventional Treatment of Chemical Pleuritis and Hemothorax Caused by Iatrogenic Internal Jugular Vein Perforation after Central Venous Port System Implantation: A Case Report
|
|
Kim Do-Woo
Kim Young-Hwan Kang Ung-Rae
|
|
Abstract
|
|
|
The perforation of the intrathoracic internal jugular vein during the placement of an implantable central venous chemoport is a rare complication that is manifested by hemothorax or hemorrhagic shock. Furthermore, inappropriate instillation of a chemotherapeutic agent in the chemoport can cause chemical pleuritis, and the diagnosis of these complications prior to the instillation of chemotherapeutic agents and open thoracic surgery is mandatory. We report a patient with chemical pleuritis and hemothorax following an inappropriate instillation of a chemotherapeutic agent, through the perforated right internal jugular vein after placement of an implantable central venous chemoport. Treatment by embolization using coils and N-butyl cyanoacrylate, after percutaneous drainage, was successful.
|
|
KEYWORD
|
|
Central Venous Catheters, Vascular System Injuries, Embolization, Therapeutic
|
|