Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1123920020160051035
Korean Journal of Oriental Physiology and Pathology
2002 Volume.16 No. 5 p.1035 ~ p.1041
Particle Size Analysis of Cadmium Aerosol for Cadmium Inhalation Toxicology Study (766ppm Cadmium Nebulizing Solution)
Jeong Jae-Yeal

Milton Donald K.
Kim Tae-Hyeung
Lee Jong-Young
Jahng Doo-Sub
Kang Sung-Ho
Song Yung-Sun
Lee Ki-Nam
Abstract
Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit and 766ppm Cd nebulizing solution were used to generate cadmium aerosol for inhalation toxicology study. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20¡É was 43.449 x 10©ø in inlet temperature 250¡É and particle diameter 0.75§­. The highest particle counting for source temperature 50¡É was 43.211 x 10©ø in inlet temperature 100 ¡É and particle diameter 0.75§­. The highest particle counting for source temperature 70¡É was 41.917x10©ø in inlet temperature 250¡É and particle diameter 0.75§­. The ranges of geometric mean diameter(GMD) were 0.677-1.009§­ in source temperature 20¡É, 0.716-0.963§­ in source temperature 50¡É, and 0.724-0.957§­ in source temperature 70¡É. The smallest GMD was 0.677§­ in source temperature 20¡É and inlet temperature 20¡É. and the largest GMD was 1.009§­ in source temperature 20¡É and inlet temperature 20¡É. The ranges of geometric standard deviation(GSD) were 1.635-2.101 in source temperature 20¡É. 1.676-2.073 in source temperature 50¡É, and 1.687-2.051 in source temperature 70¡É. The lowest GSD was 1.635 in source temperature 20¡É and inlet temperature 20¡É, and the highest GSD was 2.101 in source temperature 20¡É and inlet temperature 200¡É. Aerosol generated for cadmium inhalation toxicology study was polydisperse aerosol. The ranges of mass median diameter(MMD) were 1.399-5.270§­ in source temperature 20¡É. 1.593-4.742§­ in source temperature 50¡É, and 1.644-4.504§­ in source temperature 70¡É. The smallest MMD was 1.399§­ in source temperature 20¡É and inlet temperature 20¡É, and the largest MMD was 5.270§­ in source temperature 20¡É and inlet temperature 200¡É. Increasing trends for GMD, GSD, and MMD were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4§­. In our results. inlet temperature 20 and 50¡É in source temperature 20¡É, and inlet temperature 20 to 150¡É in source temperature 50 and 70¡É were conformed to the EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3§­. In our results, inlet temperature 20 and 50¡É in source temperature 20, 50, and 70¡É were conformed to the OECD and EU guidance.
KEYWORD
Inhalation toxicology, ultrasonic nebulizer, nebulizing solution, cadmium aerosol, particle size, particle counting, geometric mean diameter, geometric standard devaition, mass median diameter, polydisperse aerosol
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)