Diagnostic Significance of Ultrasonographic Measurements and Median-Ulnar Ratio in Carpal Tunnel Syndrome: Correlation with Nerve Conduction Studies
Ozan Volkan Yurdakul

Nilgun Mesci
Yilmaz Cetinkaya
Duygu Geler Kulcub
Abstract
Background and Purpose : We determined the reliability of ultrasonography (US) measurements for diagnosing carpal tunnel syndrome (CTS) and their correlation with symptom duration and electrophysiology findings. We determined whether the ratio of the median-to-ulnar cross-sectional areas (CSAs) can support CTS diagnoses.

Methods : The pisiform CSA (CSApisiform), swelling ratio (SR), palmar bowing, and CSApisiform/ulnar CSA (CSAulnar) measurements made in two subgroups of CTS patients (having sensory affection alone or having both sensory and motor affection) were compared with controls. CSAulnar was measured in Guyon's canal at the level of most-protuberant portion of the pisiform bone.

Results : The values of all of the measured US parameters were higher in patients with CTS (n=50) than in controls (n=62). CSApisiform could be used to diagnose CTS of mild severity. All of the parameters were positively correlated with the distal latency of the compound muscle action potential, and all of them except for SR were negatively correlated with the sensory nerve conduction velocity. A CSApisiform/CSAulnar ratio of ¡Ã1.79 had a sensitivity of 70% and a specificity of 76% for diagnosing CTS.

Conclusions : Only CSApisiform measurements were reliable for diagnosing early stages of CTS, and CSApisiform/CSAulnar had a lower diagnostic value for diagnosing CTS.
KEYWORD
carpal tunnel syndrome, musculoskeletal ultrasonography, median-ulnar ratio, nerve conduction studies, diagnosis