Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1130920060100010080
Journal of Korean Foot and Ankle Society
2006 Volume.10 No. 1 p.80 ~ p.83
The Comparison of Ultrasonographic Size of Morton¡¯s Neuroma measured to Actual Size
Kim Jae-Young

Lee Kyung-Tai
Young Ki-Won
Son Sang-Woo
Abstract
Purpose: To compare ultrasonographic size of morton¡¯s neuroma measured to actual size

Material and Methods : Thirty-two (twenty-eight patients) of symptomic Morton¡¯s neuroma were measured by ultrasonography preoperatively and by manual method that designed by authors intraoperatively from January, 2002 to May, 2003. Two results were stastically compared by paired T-test

Results:Except one, all of cases were women and the mean age of patients was 50.6 years (32-62 years). The most common associated disease was hallux valgus deformity (17 cases). Six of Morton¡¯s neuromas located on second intermetatarsal space, sixteen of them did third intemetatarsal space and ten of neuromas located simultaneously second and third intermetatarsal space. The ultrasonographic size of neuroma averaged 3.48 mm and real size was 3.99 mm. The size checked by manual method was larger than by ultrasound with statical meaning.

Conclusion:The size of Morton¡¯s interdigital neuroma checked by ultrasonography on plantar aspect is smaller than real size.
KEYWORD
Morton¡¯s neuroma, Ultrasonography
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed