KMID : 1134820090380030359
|
|
Journal of the Korean Society of Food Science and Nutrition 2009 Volume.38 No. 3 p.359 ~ p.363
|
|
Determination of Niacin in Infant Formula by Solid-phase Clean-up and HPLC with Photodiode Array Detector
|
|
Hong Jee-Eun
Kim Ok-Hee Park Eun-Ryong Mun Chun-Sun Lee Kwang-Ho Gwak In-Shin Kim Mi-Ran Cheon Sang-Hee Chai Jung-Young
|
|
Abstract
|
|
|
This study was performed to establish a rapid and simple analytical method for niacin (nicotinic acid and nicotinamide) using HPLC. A pretreatment method for the extraction and clean-up of niacin in infant formula sample and an instrumental condition for HPLC were optimized. Niacin was extracted by 5 mM hexanesulfonate with ultrasonication for 30 min. For the clean-up of the sample, the extract was applied to a HLB cartridge, and then niacin was eluted from the cartridge using 5 mL of 80% methanol after washing with 5 mL of n-hexane. The total recoveries were 83¢¦104% and relative standard deviation were in the range of 1.5¢¦3.5% during the extraction and clean-up process. Niacin was determined by gradient elution with sodium hexanesulfonate/methanol buffer as a mobile phase and a photodiode array detector (260 §¬). It showed a high linearity between the content of niacin and the peak area (r©÷=1.000) in the range of 0.02¢¦10.0 §·/L of nicotinic acid and nicotinamide. The detection limit was 0.02 §·/L (0.2 §·/§¸ in the sample). The method was successfully applied for the determination of niacin in infant formula. Total niacin contents were in the range of 53.5¢¦140.3 §·/§¸.
|
|
KEYWORD
|
|
niacin, HPLC, solid phase extraction, infant formula
|
|