Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1138520070100020081
Journal of Pharmacopuncture
2007 Volume.10 No. 2 p.81 ~ p.86
Expermental Studies of quantitative evaluation using HPLC and safety of Sweet Bee Venom
Gok Kyung-Seung

Park Hee-Soo
Kim Min-Ki
Cha Bae-Chun
Lee Eun
Kwon Ki-Rok
Abstract
Objectives : This study was conducted to carry out quantitative evaluation and safety of Sweet Bee Venom.
Methods : Content analysis was done using HPLC, measurement of LD$^{50}$ was conducted intravenous, subcutaneous, and intramuscular injection to the ICR mice.
Results : 1. According to HPLC analysis, removal of the enzymes containing phospholipase A2 was successfully rendered on Sweet Bee Venom. And analyzing melittin content, Sweet Bee Venom contained 12% more melittin than Bee Venom. 2. LD$^{50}$ of ICR mice with Sweet Bee Venom was more than 20mg/kg in subcutaneous injection and intravenous injection, between 15mg/kg and 20mg/kg in muscular injection. 3. LD$^{50}$ of ICR mice with Bee Venom was between 6 and 9mg/kg in subcutaneous injection and intravenous injection, and more than 9mg/kg in muscular injection.
Conclusion : Above results indicate that Sweet Bee Venom was more safe than Bee Venom and the process of removing enzymes was well rendered in Sweet Bee Venom.
KEYWORD
Sweet Bee Venom, Bee Venom, LD$^{50}$, HPLC analysis, melittin
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)