KMID : 1140820190140020060
|
|
Urogenital Tract Infection 2019 Volume.14 No. 2 p.60 ~ p.63
|
|
Recurrent Urinary Tract Infection from Urethral Mesh Erosion after Midurethral Mesh Sling Surgery
|
|
Han Ji-Yeon
|
|
Abstract
|
|
|
This paper presents three cases of recurrent urinary tract infections from urethral mesh erosion after transobturator midurethral sling (MUS) surgery. The patients were operated on using a MUS with a mesh for stress urinary incontinence. A few years after surgery (0.3 to 7 years), patients complained of recurrent pain in the urethra with voiding symptoms. In all cases, urethrocystoscopy was performed and an erosion of the sling directly across the urethra was found. Patients were managed by dissecting the urethra and removing the mesh via the transvaginal approach under general anesthesia.
|
|
KEYWORD
|
|
Urinary tract infections, Surgical mesh, Urethra, Stress urinary incontinence
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|