Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1141420170220020056
Korean Journal of Healthcare-associated Infection Control Prevention
2017 Volume.22 No. 2 p.56 ~ p.62
Impact of Environmental Contamination Level According to the Endotracheal Suction System in Surgical Intensive Care Unit: A Comparison of Open and Closed System
Kim Ki-Sook

Abstract
Background: This study was conducted to evaluate the level of environment contamination before and after endotracheal suctioning using an open or closed suction system in mechanically ventilated patients.

Methods: The subjects of this study included 60 patients who were mechanically ventilated from December 2016 to May 2017. Before and after application of an open or closed suction system, blood agar plates (BAPs) were placed 50 cm and 100 cm from the suction port and exposed for 30 minutes. The number of colonies in the BAP culture media was measured.

Results: There was a significant difference in the number of colonies on BAPs exposed before and after applying the open suction system at distances of 50 cm (1st; P=0.002, 2nd; P¡Â0.001) and 100 cm (1st; P=0.040, 2nd; P¡Â0.001) on both the first day and second day. There was a significant difference in the number of colonies on BAPs exposed before and after applying the closed suction system at the distance of 100 cm (P=0.009) on the first day and at the distance of 50 cm (P=0.043) on the second day. When the open suction system was applied, it was confirmed that the number of colonies was higher after than before suction.

Conclusion: The closed suction system is more effective in reducing environmental contamination in hospitals.
KEYWORD
Environmental contamination, Suction
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø