Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1143220190620020138
Obstetrics & Gynecology Science
2019 Volume.62 No. 2 p.138 ~ p.141
Hemoperitoneum: a complication of loop electrosurgical excision procedure
Cho Angela

Park Sun-Wha
Park So-Yun
Kang Hye-Sim
Shim Soon-Sup
Park Chul-Min
Kim Sung-Yob
Abstract
Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation.
KEYWORD
Conization, Laparoscopy, Hemoperitoneum
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø