Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1143220200630050675
Obstetrics & Gynecology Science
2020 Volume.63 No. 5 p.675 ~ p.678
Complications associated with intravesical migration of an intrauterine device
Rasekhjahromi Athar

Chitsazi Zohre
Khlili Azadeh
Babaarabi Zahra Zarei
Abstract
The intrauterine device (IUD) is the most common method of reversible contraception in women. However, IUD can perforate the uterus and also migrate into pelvic or abdominal organs. A 43-year-old woman with a 5-year history of IUD placement and without specific symptoms, decided to remove her IUD and undergo tubal ligation. Radiological assessment, including a pelvic X-ray and ultrasonography, revealed no copper IUD within the uterus. Retrieval attempts with cystoscopy were unsuccessful. The IUD was found embedded in the fundal part of the bladder wall and was subsequently removed through a laparotomy incision. Although there are cases in the literature that were successfully managed with cystoscopy, in chronic cases, the formation of granulation tissue may preclude retrieval of an IUD using this intervention.
KEYWORD
Intrauterine devices, Contraception, Migration, Bladder