Biomedical Engineering Letters
2018 Volume.8 No. 3 p.329 ~ p.335
The effect of mechanical or electrical stimulation on apnea length in mice
Jawde Samer Bou

Scheuermann Alexandra
Bartolak-Suki Erzsebet
Suki Bela
Abstract
Premature birth is a leading cause of infant mortality which is often attributed to irregular breathing and apnea of prematurity. A common treatment for apnea is caffeine to stimulate the brain¡¯s respiratory center. However, caffeine¡¯s long term effect on infant development is not fully comprehended. We hypothesized that noninvasive localized body stimulation regularizes breathing pattern. We investigated the impact of electrical or mechanical stimulation on breathing in mice. After the mice were ventilated for 28 s to induce apnea, mice were taken off the ventilator while receiving mechanical, electrical, or no stimulation in a randomized order. Both stimuli targeted the diaphragm area through a custom-built belt with vibrating motors or adhesive electrodes. After each apnea cycle, the time to take the first breath (T) was recorded. The electrical stimulation given at 4.5, 8.3, 16.7 V (pulse rate?=?3 Hz, pulse width?=?120 ¥ìs) showed no reduction in T. Electrical stimulation at pulse rates of 10 or 20 Hz (16.7 V, pulse width 260 ¥ìs) showed a detrimental effect increasing T by?~?7% compared to control values (p?=?0.005, p?=?0.038 respectively). High and medium intensity mechanical stimulations significantly reduced T by 11.74 (p?
KEYWORD
Apnea of prematurity, Breathing regulation, Noninvasive, Mechanical vibrations, Electrical stimulation