KMID : 1144520210330010027
|
|
Knee Surgery & Related Research 2021 Volume.33 No. 1 p.27 ~ p.27
|
|
Clinical outcomes of two-stage revision total knee arthroplasty in infected cases with antibiotic-loaded cement spacers produced using a handmade silicone mold
|
|
Hoshino Takashi
Watanabe Toshifumi Nakagawa Yusuke Katagiri Hiroki Ozeki Nobutake Ohara Toshiyuki Shioda Mikio Kono Yuji Sekiya Ichiro Koga Hideyuki
|
|
Abstract
|
|
|
Purpose: This study assessed the clinical outcomes of periprosthetic joint infection patients who underwent two-stage revision total knee arthroplasty with antibiotic-loaded cement spacers fabricated using a handmade silicone mold.
Materials and methods: This study included seven patients (average age 77?years, average follow-up time 54?months) who underwent surgery at our hospital between 2009 and 2013. Clinical outcomes including knee scores, function scores, knee range of motion, and walking ability at the final observation, period from the primary total knee arthroplasty to implant removal, period from implant removal to revision total knee arthroplasty, and follow-up period after revision total knee arthroplasty were investigated.
Results: At the final follow-up, the average knee range of motion was 99¡Æ, with no significant differences at each stage; average knee and function scores were 84 and 77, respectively. With cement spacers, five patients were able to walk with a t-cane. No recurrence of infection was observed.
Conclusions: The clinical outcomes of the current case series demonstrated good knee function with preserved walking ability, without any recurrence of periprosthetic joint infection. This study suggests that using a handmade silicone mold could be an effective option for periprosthetic joint infection after a total knee arthroplasty.
|
|
KEYWORD
|
|
Periprosthetic joint infection, Total knee arthroplasty, Two-stage revision, Cement spacer, Hand-made silicon mold
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|
|