A study of 99mTc-sestamibi labeling condition using radio-chromatography
Moon Sung-Hyun

Lee Yun-Sang
Lee Dong-Soo
Chung June-Key
Jeong Jae-Min
Abstract
Tc-99m labeled sestamibi (99mTc-MIBI) is one of most widely used radiopharmaceuticals for myocardial SPECT imaging. Radiolabeling of 99mTc-MIBI is recommended by heating in 100¡ÆC water bath for 15 min. However, the water bath might be a source of contamination. Thus, if radiolabeling of 99mTc-sestamibi can be performed at room temperature, then it would be more convenient to use in clinical application. In this study, we performed the radiolabeling of 99mTc-MIBI in different temperature conditions or using different instruments to find out the efficient labeling condition. We studied the 99mTc-MIBI labeling at room temperature or 100oC heating block, and checked the labelling yields every 1 min for 10 min using radio-TLC with 2 different eluents?saline and acetone. From the experiment, we confirmed that the 99mTc-MIBI can be labeled over 90% yield but not completed at room temperature. However, the 99mTc-MIBI labeling was completed when it was performed in the 100oC heating block. Finally, we proved that heating is essential for complete 99mTc-MIBI labelling, furthermore using heating block is also possible instead of water bath.
KEYWORD
99mTc-MIBI, Sestamibi, Radio TLC, Labelling condition