Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1148120150050010017
Journal of Advanced Spine Surgery
2015 Volume.5 No. 1 p.17 ~ p.22
A New Method for Volumetric Assessment of Fusion Mass After Posterior Lumbar Interbody Fusion
Kim Ho-Joong

Lee Sun-Hyung
Kang Kyoung-Tak
Chang Bong-Soon
Lee Choon-Ki
Yeom Jin-S.
Abstract
Purpose: To assess the volume of fusion mass after posterior lumbar interbody fusion (PLIF) using Hounsfield units methods.

Methods: The present study was within the frame work about a prospective observational cohort study to compare the surgical outcomes of a single-level PLIF for LSS between the local bone (LbG) and local bone plus hydroxyapatite groups (LbHa). The fusion material for each case was determined by the amount of available local bone. After the fusion material was chosen, patients were assigned to either the LbG group (n=20) or the LbHa group (n=20). The primary outcome was the assessment of fusion mass volume in each group.

Results: We used the new method using Hounsfield units for volumetric assessments of interbody fusion mass. There was no difference in fusion rates or volume of the fusion mass between the 2 groups.

Conclusions: Hounsfield unit method, that is the CT-based summation method using a cross-sectional slice, can be applied usefully to other areas of orthopaedics.
KEYWORD
Hounsfield units, Hydroxyapatite, Posterior lumbar interbody fusion, Bone transplantation
FullTexts / Linksout information
Listed journal information