A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Tadiation Yherapy on Prostate Cancer
Kim Young-Jae

Lee Jae-Sub
Hong Seong-Il
Ko Hye-Jin
Abstract
In this study, we evaluated to the superiority of treatment techniques on prostate cancer, apply to each other treatment techniques-3D conformal therapy versus IMRT-using dose distribution and dose coverages. Obtained 10 patients CT simulation, divided tumor volume and critical organs. Prescription dose was 80 Gy on tumor volume and Each of plans was set by two different plans. As a result, Dose coverage was superior to IMRT. The IMRT's tumor absorbed dose(100.2%) was close to prescription doses. Normal tissue(bladder, rectal, bowel Lt Rt fumoral head) absorbed dose rate was superior. In other words, the radiation therapy of prostate cancer with intensity modulated radiation therapy was better than conformal radiation therapy on dose.
KEYWORD
3D-Conformal Radiation Therapy, IMRT, Prostate cancer