Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1151820140080060333
Journal of the Korean Society of Radiology
2014 Volume.8 No. 6 p.333 ~ p.338
The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction
Kang Sang-Sik

Kim Kyo-Tae
Noh Si-Cheol
Joeng Bong-Jae
Park Ji-Koon
Abstract
The fact is that in addition to an increase in social needs that must be managed systematically unnecessary exposure in the field of medical Recent important that the shield has emerged. However, products that are now in practical use, are not subdivided as compared to various medical radiology. Therefore, in the present study, we tried to present with the help of Monte Carlo simulation the structure of the shielding material that has been optimized. Simulated estimation result, the energy of the mammography for (30 kVp) spectrum, check the shielding rate of 90% or more 30¥ìmPb, at 2 mmAl case of shielding material of a single, at design time of 1 mmAl and 0.03 mmPb a double shield structure it is determined that more efficient. Also, check the blocking rate of 90% or more 340¥ìmPb, at 30 mmAl energy captured general in (80 kVp) spectra, it is considered that a double shield structure, design 1 mmAl and 0.3 mmPb is useful. These results, be used as basic material for the development of commercialization customized products for dose reduction is expected.
KEYWORD
Monte Carlo Simulation, Double-shielded structure, Lead, Aluminium, Shielding rate
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)