Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1151820160100040233
Journal of the Korean Society of Radiology
2016 Volume.10 No. 4 p.233 ~ p.239
Comparison of Dose Distribution between the Techniques of Non-small Cell Lung Cancer
Lee Seung-Chul

Kim Young-Jae
Jang Seong-Joo
Abstract
Comparison of the dose aspect that radiation therapy treatments using IMRT, tomotherapy, mArc (modulated arc therapy). The experimental subject is non-small cell lung cancer patient. The prescription dose is 58.0 Gy to the volume of PTV(planning target volume). and spinal cord, esophagus, and liver organ is the normal organ(OAR, organ at risk). Average PTV value is 57.60 Gy in mArc and 61.04 Gy in tomotherapy and 58.95 Gy in IMRT. The average dose of the Esophagus is 2.84 Gy in m-Arc, 5.14 Gy in tomotherapy, 1.84 Gy in IMRT. The average dose of the Liver is 19.44 Gy in m-Arc, 12.22 Gy in tomotherapy, 21.97 Gy in IMRT. The average dose of the Spinal cord is 5.72 Gy in m-Arc, 7.08 Gy in tomotherapy, 6.15 Gy in IMRT. Results of this study is no significant difference between mArc and tomotherapy and Linac based IMRT in dose study and also, mArc's dose coverage and dose volume histogram is better than IMRT and tomotherapy. but, This study is limited to a disease of cancer. in addition, fewer number of groups. The wide range the more research can be developed patient-specific treatment techniques and be applied to the patients
KEYWORD
Non small cell lung cancer, Radiation Therapy, IMRT
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)