Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1151820170110060443
Journal of the Korean Society of Radiology
2017 Volume.11 No. 6 p.443 ~ p.451
Evaluation and Comparison of Signal to Noise Ratio According to Change of Kernel size of Heart Shadow on Chest Image
Lee Eul-Kyu

Jeong Hoi-Woun
Min Jung-Whan
Abstract
The purpose of this study was to comparison of measure signal to noise ratio (SNR) according to change of kernel size from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 100 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p<0.05). In SNR results, with the quality of distributions in the order of kernel size 9*9 image, kernel size 7*7 image and original chest image, kernel size 3*3 image (p<0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the kernel size chest image.
KEYWORD
Chest image, Signal to noise ratio, Kernel size, Edge enhancement, Post processing
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)