Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University
Kim Jung-Su

Abstract
Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and 14 Bq/m3 respectively and average indoor radon concentration represented 41.63 Bq/m3 . Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.
KEYWORD
radon concentration, effective dose, natural radioactive materials, internal exposure, ¥á ray