Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1151820190130010045
Journal of the Korean Society of Radiology
2019 Volume.13 No. 1 p.45 ~ p.53
Comparison of General Concrete and Low-radiation Concrete as Shielding Materials for Medical Linear Accelerators
Lee Dong-Yeon

Kim Jung-Hoon
Abstract
This study is a neutron activation for concrete that shields medical linear accelerator facilities. Comparison of general concrete and low activation concrete. The simulation method was simulated using MCNPX (Ver. 2.5.0) and FISPACT-2010, and the shielding ability for photon and neutron beams was calculated and neutron activation evaluation was carried out. As a result, the shielding capacity was 20 ~ 50 cm efficient in general concrete, and activate evaluation in low activation concrete was calculated to be low in radioactivity concrete, but all were estimated to not exceed their own allowable concentration in self - disposal. As a result of the comprehensive analysis, it is considered effective to use ordinary concrete.
KEYWORD
LINAC, Activation, MCNPX, Fispact-2010, Concrete
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)