Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1155520110060010045
Anesthesia and Pain Medicine
2011 Volume.6 No. 1 p.45 ~ p.49
Catheter malposition rate following right subclavian venous catheterization
Lee Dong-Jun

Kim Moon-Chul
Abstract
Background: Malposition of a central venous catheter may cause several complications such as poor function of the catheter or cardiac tamponade. This study was designed to determine the incidence of malposition after subclavian venous catheterization at the university hospital.

Methods: We prospectively examined catheter locations from 367 subclavian vein catheterizations by an infraclavicular approach using postoperative chest X-rays to analyze the rate of catheter malposition.

Results: Primary misplacement was observed in 29 cases (7.9%). Seventeen cases were located in the right internal jugular vein, 8 cases (2.2%) were located in the left subclavian vein, 2 cases (0.5%) were located inside the right atrium, 1 catheter (0.3%) was kinking in the right subclavian vein and 1 catheter (0.3%) was located in the right brachiocephalic vein.

Conclusions : Using the infraclavicular approach for subclavian catheterization, a central venous catheter was most commonly misplaced in the ipsilateral internal jugular vein. Operators must keep in mind that even experienced practitioners may cause a considerable number of malpositions and it is very important to check the chest X-ray to locate the catheter malposition after central venous catheterization.
KEYWORD
Catheterization, Central venous, Malposition
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø