Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1155520120070010045
Anesthesia and Pain Medicine
2012 Volume.7 No. 1 p.45 ~ p.50
Heart rate variability predicts the extent of corrected QT interval prolongation after tracheal intubation
Kim Ji-Young

Shim Yon-Hee
Choi Seung-Ho
Ham Sung-Yeon
Abstract
Background: Corrected QT (QTc) interval can be modulated by sympathetic and parasympathetic balance. Tracheal intubation causes significant prolongation of the QTc interval due to sympathetic stimulation. This study was designed to elucidate the relationship between baseline autonomic nervous system activity and QTc prolongation after endotracheal intubation using heart rate variability (HRV).

Methods: Sixty-six healthy patients were included and the baseline HRV data were recorded for 5 min before anesthesia. Power spectrum densities were calculated for low frequencies (LF, 0.04?0.15 Hz) and high frequencies (HF, 0.15?0.4 Hz), defined as either LF¡¯s or HF¡¯s relative part of the total power. Anesthesia was induced with sevoflurane and vecuronium was given. The QTc interval, heart rate (HR) and mean arterial pressure (MAP) were measured before induction (baseline), before laryngoscopy (pre-intubation) and immediately after the intubation (post-intubation).

Results: The QTc interval change at post-intubation from baseline (?QTc) showed a significant negative correlation with the HF (r = 0.34, P = 0.006) and positive correlation with LF/HF ratio (r = 0.37, P = 0.005). Patients were retrospectively divided into low-HF/ LF (£¼2.5, n = 44) and high-HF/LF group (£¾2.5, n = 22). The ?QTc was statistically higher in the high-LF/HF group compared to that in the low-LF/HF group (P = 0.048). The HR and MAP at baseline, pre-intubation and post-intubation were not different between two groups.

Conslusions: The QTc interval prolongation after endotracheal intubation is influenced by baseline autonomic conditions and can be exaggerated in patients with activated sympathetic activity or depressed parasympathetic activity.
KEYWORD
Autonomic nervous system, Corrected QT interval, Heart rate variability, Intubation
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø