KMID : 1155520120070020147
|
|
Anesthesia and Pain Medicine 2012 Volume.7 No. 2 p.147 ~ p.150
|
|
Endotracheal intubation using i-gel and a flexible fiber optic bronchoscope -A case report-
|
|
Lim Hyun-Kyoung
Choi Chun-Gil Shinn Helen-Ki Lee Choon-Soo Hwang Sung-Il Lee Seong-Muk Song Jang-Ho
|
|
Abstract
|
|
|
Most anesthesiologists, at one point or another, are faced with a difficult airway. We came upon an unexpected difficult airway and a failed intubation using a direct laryngoscope and lightwand. At this point, we decided to insert an i-gel which is quick and simple. This allowed us to maintain oxygenation and ventilation. After checking for the location of the laryngeal inlet with a flexible fiber optic bronchoscope, a 5.5 mm internal diameter endotracheal tube was inserted into the trachea over the flexible fiber optic bronchoscope. Finally, a suitable a 7.0 mm internal diameter endotracheal tube was inserted using an exchange catheter technique. With respect to this case, we conclused that the i-gel is a very helpful device for endotracheal intubation in patients with difficult airways.
|
|
KEYWORD
|
|
Difficult intubation, Fiberoptic, Supraglottic airway
|
|