Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1155520170120020151
Anesthesia and Pain Medicine
2017 Volume.12 No. 2 p.151 ~ p.154
Tension hydrothorax induced by malposition of central venous catheter -A case report-
Ki Seung-Hee

Kim Myoung-Hun
Lee Won-Jin
Cho Hak-Moo
Abstract
Central venous catheterization is a useful method for monitoring central venous pressure and maintaining volume status. However, it is associated with several complications, such as pneumothorax, hydrothorax, hemothorax, and air embolism. Here we describe a case of iatrogenic tension hydrothorax after rapid infusion of fluid into the pleural space, following the misplacement of an internal jugular vein catheter. Despite ultrasonographic guidance during insertion of the central venous catheter, we were not able to avoid malposition of the catheter. The patient went into hemodynamic compromise during surgery, necessitating chest tube drainage and a mechanical ventilator postoperatively. This case shows that central venous catheter insertion under ultrasonographic guidance does not guarantee proper positioning of the catheter.
KEYWORD
Central venous catheterization, Hydrothorax, Tension
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø