Acute traumatic injury and delayed airway obstruction after the use of a GlideScope in a patient with a difficult airway -A case report-
Song Seung-Hyun

Lee Won-Hyung
Chung Woo-Suk
Lee Ji-Yong
Ann Misun-Youn
Abstract
Endotracheal intubation sometimes leads to complications, particularly in patients with anticipated difficult intubation. The GlideScope is preferred because of its high success rate in cases with anticipated difficult intubation. However, complications during the process have been reported. Most minor injuries can be treated after early detection. However, treatment can be difficult if complications occur later. We report a patient who underwent an emergency tracheostomy due to a delayed airway obstruction caused by pharyngeal wall bleeding during intubation with a GlideScope.