Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1159320070090030283
Korean Journal of Vision Science
2007 Volume.9 No. 3 p.283 ~ p.289
The Comparison of Autorefractometry and Retinoscopy using Cycloplegic Material
Jung JI-Won

Kim Tae-Hun
Sung A-Young
Abstract
This study was carried out on 288 eyes of 144 primary school students who didn¡¯t have strabismus or amblyopia, had never worn glasses, and complained about naked acuity. The change of refractive error for noncycloplegic and cycloplegic were measured using autorefractometer and retinoscope. The spherical equivalents of noncycloplegic and cycloplegic measured using autorefractometer were -1.40D¡¾1.04 and -0.77D¡¾1.32, respectively, showing that the cycloplegic refraction was significantly lower than manifest refraction by approximately -0.63D(t = -13.49, p < 0.05). With the retinoscope as well, the spherical equivalents for noncycloplegic and cycloplegic were -1.06D¡¾1.03 and -0.91D¡¾1.27, respectively, showing that the cycloplegic refraction was significantly lower than the manifest refraction by approximately -0.15D(t = -4.17, p < 0.05).
KEYWORD
Autorefractometry, Retinoscopy, Manifest refraction, Cycloplegic refraction, Accommodation