Korean Journal of Vision Science
2008 Volume.10 No. 3 p.177 ~ p.187
Study on the Correlation between Refractive Error and Ocular Components
Jung Mi-A

Lee Hae-Jung
Jung Se-Ju
Song Yun-Young
Choi Jeong-Hoon
Abstract
Purpose: This study investigates the prevalence of refractive error and to study the ocular biometric correlates of refractive error.

Methods: Refractive error and ocular biometry were measured in 68 adults(68 eyes) with healthy eyes. Spherical equivalent refraction, corneal power and mean corneal radius were measured using a Topcon KR-8800 autorefractor. Anterior chamber depth, crystalline lens thickness, vitreous chamber depth and axial length measurements were made using A-scan ultrasonography. AL/CR ratio was calculated by dividing axial length measurements by mean corneal radius.

Results: Spherical equivalent refractions were measured by -3.55¡¾2.84D(males -3.73¡¾ 3.21D, females -3.40¡¾2.55D), and not differ significantly between males and females. Prevalence of spherical equivalent refraction were as follows : myopes (60eyes, 88.24%), emmetropes(6eyes, 8.82%), hyperopes(2eyes, 2.94%). Groupaveraged spherical equivalent refractions were as follows : myopes(-4.02¡¾ 2.69D), emmetropes(-0.33¡¾0.13D), hyperopes(+0.88¡¾0.18D). Astigmatism of at least 0.75D was evident in 51.47%(35 eyes) of the subject cohort. Astigmatism for these groups was as follows : with-the rule astigmatism(33eyes, 94.29%), oblique astigmatism (2eyes, 5.71%). Regression analysis of corneal toricity against ocular astigmatism revealed a strong negative correlation(r = -0.84, p < 0.0001). AL/CR ratio against refractive error were measured by emmetropes(2.93¡¾0.02), myopes(3.12¡¾0.14), and hyperopes(2.87¡¾0.01). Linear regression analysis showed that AL/CR ratio correlated most closely with spherical equivalent refraction(r = -0.88, p < 0.0001).

Conslusions: A strong correlation was found between axial length and spherical equivalent refraction and the principal factor in refractive error is axial length. Analysis of biometric data has shown that AL/CR ratio has the highest negative correlation with spherical equivalent refraction, thus supporting previous studies. With-the-rule astigmatism was more prevalent than other astigmatism in this study. A strong negative correlation was found between corneal toricity and astigmatism, the principal factor in ocular astigmatism is corneal toricity.
KEYWORD
Anterior chamber depth, Axial length, Corneal power, Spherical equivalent refraction, Vitreous chamber depth