Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1171820060210010035
Journal of Environmental and Sanitary Engineering
2006 Volume.21 No. 1 p.35 ~ p.43
Analysis of formaldehyde using DNPH cartridge/LC-MS in the Ban-Woll¤ýShi-Hwa Industrial Complex
Cho Deok-Hee

Song Il-Seok
Kim In-Gu
Kim Woong-Soo
Kim Jong-Bo
Kim Tae-Hyun
Hwang Sun-Min
Nam Woo-Kyong
Abstract
Formaldehyde is important because of their irritant and toxic properties, mutagenicity and carcinogenicity. In this study, liquid chromatography-mass spectrometry (LC-MS) is used for the analysis of formaldehyde after derivatization with 2,4-dinitrophenylhydrazine (DNPH) cartridge. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearity (r©÷) was 0.9997 when analyte concentration ranges from 25 to 200 §¶/§¤. The relative standard deviation (%RSD) was 1.25 % for concentration of 200 §¶/§¤. The minimum detection limit (MDL) was 0.73 ppbv. It was shown that LC-MS method has a great potential for formaldehyde analysis. The results of formaldehyde from the survey of Ban-Woll and Shi-Hwa Industrial Complex samples, the highest level was 6.20, 3.93 ppb, respectively. The highest emission level of formaldehyde at chemical plants in the Ban-Woll¤ýShi-Hwa Industrial Complex was 5421.25 ppb.
KEYWORD
Formaldehyde, DNPH cartridge, LC-MS, Ban-Woll¤ýShi-Hwa Industrial Complex
FullTexts / Linksout information
Listed journal information