KMID : 1171820090240040060
|
|
Journal of Environmental and Sanitary Engineering 2009 Volume.24 No. 4 p.60 ~ p.68
|
|
The Removal Effect of Fine Particles Applied Platform Screen Door in Seoul Subway Station
|
|
Sohn Jong-Ryeul
Jung Young-Rim Park Hyun-Hee Oh Youn-Hee Choi Won Kim Soon-Geun
|
|
Abstract
|
|
|
The most principal approach to improve indoor air quality(IAQ) of subway was to examine the fine particulate(PM-10) from the emission sources. Therefore, this study was carried on the investigation the fine particulate for comparison with the removal efficiency of PM-10 in divided the PSD(Platform Screen Door) and Non-PSD subway station from July, 2007 to May 2008. In the monitoring results, the range of PM-10 concentration of Non-PSD station was 44.6¡116.5§¶/§© and the range of PM-10 concentration of PSD station was 23.9¡81.1§¶/§©. And then the range of PM-2.5 concentration of Non-PSD station was 17.4-56.6§¶/§©, and then the range of PM-2.5 concentration of PSD station was 17.9¡34.4§¶/§©. In comparison with the results of the PSD and Non-PSD subway station, we found that the PM-10 removal efficiency of PSD was 30-40%. In conclusion, the PSD will be applied the effective facilities of decreasing PM-10 in subway station in Korea.
|
|
KEYWORD
|
|
Subway, IAQ, Fine particles, Platform screen door(PSD)
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|