Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1207720120040020117
Clinics in Orthopedic Surgery
2012 Volume.4 No. 2 p.117 ~ p.120
The Conversion Rate of Bipolar Hemiarthroplasty after a Hip Fracture to a Total Hip Arthroplasty
Alazzawi Sulaiman

De Rover Walter B Sprenger
Brown James
Davis Ben
Abstract
Background: Bipolar hip hemiarthroplasty is used in the management of fractures of the proximal femur. The dual articulation is cited as advantageous in comparison to unipolar prostheses as it decreases acetabular erosion, has a lower dislocation rates and is easier to convert to a total hip arthroplasty (THA) should the need arise. However, these claims are debatable. Our study examines the rate of conversion of the bipolar hemiarthroplasty to THA and the justification for using it on the basis of future conversion to THA.

Methods: All cases of bipolar hemiarthroplasty performed in our unit for hip fractures over a 9-year period (1999-2007) were reviewed. Medical notes and radiographs of all patients were reviewed, and all surviving patients that were contactable received a telephone follow-up.

Results: Of all 164 patients reviewed with a minimum of 1 year from date of surgery, 4 patients had undergone a conversion of their bipolar prosthesis to THA. Three conversions were performed for infection, dislocation, and fracture. Only one (0.6%) conversion was performed for groin pain.

Conclusions: Our study show that bipolar hemiarthroplasties for hip fractures have a low conversion rate to THAs and this is comparable to the published conversion rate of unipolar hemiarthroplasties.
KEYWORD
Hip fracture, Bipolar arthroplasty, Total hip arthroplasty
FullTexts / Linksout information
 
Listed journal information
MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed