Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1207720150070020177
Clinics in Orthopedic Surgery
2015 Volume.7 No. 2 p.177 ~ p.184
The Results of All-Inside Meniscus Repair Using the Viper Repair System Simultaneously with Anterior Cruciate Ligament Reconstruction
Kang Hong-Je

Chun Churl-Hong
Kim Kwang-Mee
Cho Hang-Hwan
Johnsel C. Espinosa
Abstract
Background: Meniscus tears are commonly associated with anterior cruciate ligament (ACL) ruptures. It is essential to repair meniscal tears as much as possible to prevent early osteoarthritis and to gain additional stability in the knee joint. We evaluated the results of arthroscopic all-inside repair using the Meniscal Viper Repair System (Arthrex) on meniscus tears simultaneously with ACL reconstruction.

Methods: Nineteen out of 22 patients who were treated with arthroscopic all-inside repair using the Meniscal Viper Repair System for meniscus tear associated with ACL rupture were evaluated. ACL reconstructions were performed at the same period. The mean follow-up period was 16.5 months (range, 12 to 24 months). The clinical results of the meniscus repair were evaluated by symptoms (such as catching or locking), tenderness, effusion, range of motion limitation, and the McMurray test. Clinical success was defined by negative results in all five categories. The Hospital for Special Surgery (HSS) score was evaluated. Objective results were evaluated with secondary look arthroscopy or magnetic resonance imaging (MRI). The MRI results were categorized as completely repaired, incompletely repaired, and failure by Henning's classification. The results of second-look arthroscopy were evaluated with the criteria of meniscal healing.

Results: The clinical success rate was 95.4% and the HSS scores were 93.9 ¡¾ 5.4 at the final follow-up. According to Henning's classification, 15 out of 18 cases showed complete healing (83.3%) and two cases (11.1%) showed incomplete healing. Seventeen out of 18 cases that underwent second-look arthroscopy showed complete healing (94.4%) according to the criteria of meniscal healing. Only one case showed failure and the failure was due to a re-rupture at the sutured area. Complications of ACL reconstruction or meniscus repair were not present.

Conclusions: The results demonstrate that arthroscopic all-inside repair using the Meniscal Viper Repair System is an effective treatment method when it is performed simultaneously with ACL reconstruction.
KEYWORD
Anterior cruciate ligament, Meniscus, Reapir, Viper, All inside
FullTexts / Linksout information
 
Listed journal information