Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1207720170090010043
Clinics in Orthopedic Surgery
2017 Volume.9 No. 1 p.43 ~ p.49
Is Intraoperative Use of QuikClot Combat Gauze Effective for Hemostasis after Total Knee Arthroplasty?
Noh Jung-Ho

Lee Jae-Woo
Nam Young-Joon
Choi Ki-Yong
Abstract
Background: To assess the hemostatic effect of QuikClot Combat Gauze (QCG) compared to that of standard gauze during cruciate-retaining total knee arthroplasty (TKA).

Methods: Sixty knees underwent TKA using a pneumatic tourniquet in this prospective randomized study. After implantation of the femoral and tibial components and hardening of the bone cement, the tourniquet was deflated and QCG (group 1) or standard gauze (group 2) was packed into the joint cavity for 5 minutes for hemostasis. Perioperative bleeding volume and blood transfusion volume were compared between two groups.

Results: The mean intraoperative bleeding volume was 64.7 ¡¾ 12.7 mL in group 1 and 63.9 ¡¾ 9.2 mL in group 2 (p = 0.808). The mean postoperative blood drainage was 349.0 ¡¾ 170.6 mL in group 1 and 270.1 ¡¾ 136.3 mL in group 2 (p = 0.057). The average postoperative blood transfusion volume was 323.7 ¡¾ 325.9 mL in group 1 and 403.6 ¡¾ 274.8 mL in group 2 (p = 0.314).

Conclusions: QCG was not significantly effective for reducing perioperative bleeding volume or the blood transfusion rate compared with standard gauze during TKA.
KEYWORD
Knee, Replacement, Arthroplasty, Hemostasis, QuikClot Combat Gauze
FullTexts / Linksout information
 
Listed journal information
MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed