Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1207720200120010043
Clinics in Orthopedic Surgery
2020 Volume.12 No. 1 p.43 ~ p.48
Contamination Rate of Burnt Necrotic Tissue after Electrocoagulation in Total Knee Arthroplasty
Rattanaprichavej Piti

Laoruengthana Artit
Galassi Monton
Weerakul Santi
Rasamimongkol Supachok
Abstract
Background: Periprosthetic joint infection (PJI) is one of the commonly found catastrophic complications after total knee arthroplasty (TKA). Preoperative antibiotic prophylaxis, proper skin cleansing, shortened operative time, and sterility of surgical field and equipment are essential to minimize the risk of PJI. Although bacterial contamination of electrocautery tips has been reported, contamination of residual product of electrocoagulation, burnt necrotic tissue (BNT), is not well known. Therefore, we aimed to assess the contamination rate of BNT and association between contaminated BNT and PJI, and risk factors.

Methods: BNTs from 183 patients who had undergone unilateral primary TKA at our institution were retrospectively analyzed. In each patient, three to five specimens of BNT were routinely collected in the operative field of primary TKA. Collecting time was defined as the duration from start of using the electrocautery device to the first collection of BNT.

Results: Culture was positive in eight of 183 patients (4.4%; contaminated BNT group), and the most commonly isolated organism was coagulase-negative Staphylococcus (62.5%). The average operative time was 103.1 ¡¾ 44.2 minutes in the contaminated BNT group and 79.0 ¡¾ 16.7 minutes in the non-contaminated BNT group (p = 0.17), and collecting time was 48.0 ¡¾ 44.3 minutes and 29.7 ¡¾ 17.0 minutes (p = 0.28), respectively. None of the patients with contaminated BNT developed PJI, whereas four patients with culture-negative BNT developed PJI within 2 postoperative years.

Conclusions: BNT in surgical field can become a reservoir of contaminating bacteria. However, contamination of BNT was not associated with PJI. Therefore, routine removal of all BNTs may be unnecessary.
KEYWORD
Knee, Prosthesis-related infections, Arthroplasty, Electrocoagulation, Surgical instruments
FullTexts / Linksout information
  
Listed journal information
MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed