Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1207720220140010096
Clinics in Orthopedic Surgery
2022 Volume.14 No. 1 p.96 ~ p.104
Comparison of Patellofemoral Outcomes between Attune and PFC Sigma Designs: A Prospective Matched-Pair Analysis
Maniar Rajesh Navin

Bhatnagar Nishit
Bidwai Rohan
Dhiman Ankur
Chanda Debashish
Sanghavi Nishant
Abstract
Backgroud: Attune (DePuy Synthes) prosthesis was designed to overcome patellofemoral complications associated with PFC Sigma (DePuy Synthes) prosthesis. The aim of our study was to compare the incidence of anterior knee pain (AKP), patellofemoral crepitus (PCr), and functional outcome between them.

Methods: This prospective matched-pair study was conducted between January 2014 and June 2015, during which 75 consecutive Attune total knee arthroplasties (TKAs) were matched with 75 PFC Sigma TKAs based on age, sex, body mass index, pathology, and deformity. A single surgeon performed all the operations with aid of computer navigation, using a posterior-stabilized prosthesis with patellar resurfacing. Outcome was assessed by new Knee Society Score (NKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. AKP and PCr were assessed by a patient-administered questionnaire till 2 years of follow-up. Three pairs were lost to follow-up and finally 72 pairs were analyzed.

Results: One patient in each group reported AKP and 1 patient from each group had PCr at 2 years postoperatively. None of these patients required additional surgery. The incidence of lateral retinacular release was higher with PFC Sigma (5/72) than Attune (2/72); however, this was statistically not significant (p = 0.4). The Attune group had a significantly greater range of motion (ROM) at 3 months postoperatively (p = 0.049). At final follow-up, ROM was comparable between two prosthesis designs. NKSS and WOMAC scores were also comparable between the groups.

Conclusions: We observed that both Attune and PFC Sigma had a low and comparable incidence of AKP and PCr up to 2 years of follow-up. The Attune group achieved a significantly greater ROM at 3 months postoperatively. At 2 years of follow-up, both prostheses had excellent and comparable clinical and functional results.
KEYWORD
Knee, Prosthesis design, Patellofemoral joints, Arthroplasty, Anterior knee pain syndrome
FullTexts / Linksout information
 
Listed journal information
MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed