Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385920220330030233
Journal of the Korean Society of Emergency Medicine
2022 Volume.33 No. 3 p.233 ~ p.238
Measurement of height of the cricothyroid membrane using cervical-spine computed tomography
Lee Min-Ho

Seol Seung-Hwan
Woo Seon-Hee
Lee Woon-Jeong
Kim Dae-Hee
Lee June-Young
Kim Ji-Hoon
Park Sang-Hyun
Abstract
Objective: Emergency cricothyroidotomy is an infrequently performed procedure and post-procedural complications may result from attempting to pass a device with a large external diameter through the cricothyroid membrane. This study aimed to determine the maximum height of the cricothyroid membrane according to the patient¡¯s sex and age based on cervical-spine computed tomography (C-spine CT) in the emergency department (ED) and determine the appropriate endotracheal tube (ETT) size.

Methods: A retrospective analysis of patients was conducted from May 2014 to April 2020 in the ED. The data were obtained from medical records. Electronic calipers were used to measure the maximum height of the cricothyroid membrane in C-spine CT by an emergency physician and an emergency medicine resident.

Results: Six hundred and sixty-four patients were included in the study. The mean height of the cricothyroid membrane was 10.11¡¾2.24 mm in males (n=351) and 8.90¡¾1.84 mm in females (n=313) (P<0.001). In males, the cricothyroid membrane height showed significant variance between the ¡Ã75-year-old and the 25-34-year-old groups (9.26¡¾2.40 mm vs. 11.80¡¾2.36 mm) (P<0.001). The tube size of the cricothyroidotomy equipment was suitable for more than 72.1% of patients when applied with an ETT (internal diameter ¡Â6.0 mm).

Conclusion: This study showed that the height of the cricothyroid membrane differed according to sex and also age in males. It may thus be necessary to consider anatomical differences according to sex and age when selecting the appropriate tube size to reduce complications during emergency cricothyroidotomy.
KEYWORD
Airway management, Cricothyroid membrane, multi-detector computed tomography
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø