Determination of Trap Parameters of TLD using Glow Curve Fitting
|
|
Park Myeong-Hwan
Kim Seong-Hwan
|
|
Abstract
|
|
|
Highly sensitive CaSO©þ:Tm TLD are fabricated and their trap parameters are determined. The glow curve of CaSO©þ£ºTm consists of three glow peaks and these peaks are isolated by the thermal bleaching method. The isolated glow peaks are fitted by a least squares method. The activation energies are 0.68, 0.82 and 1.03 eV. The frequency factors are 8.09¡¿10^(£¶), 9.14¡¿10^(£¸) and 1.03¡¿10^(£¹)/s, and the kinetic orders are 1.37, 1.54 and 1.68, respectively. The optimun temperature range of the main peak for radiation dosimetry is 220~290¡É.
|
|