Effect of Non-thermal Dielectric Barrier Discharge Plasma by Air Volume against Mycobacterium Tuberculosis
Son Eun-Soon

Kim Yong-Hee
Paik Nam-Won
Lee Il-Young
Kim Eun-Hwa
Park Hae-Ryoung
Lee Jong-Seok
Abstract
Objectives: The objective of this study was to evaluate the inhibitory effect of non-thermal dielectric barrier discharge (DBD) plasma by air volume against Mycobacterium tuberculosis (MTB).

Methods: Plasma generators (TB-300, Shinyoung Airtec, Seongnam-si, Korea) were operated in a 2A type biosafety cabinet. The plasma generator was set to a wind flow rate of 14 (80 m3/h), 18 (110 m3/h), and 22 (150 m3/h), and exposure times were set to 0 hours, 3 hours, 6 hours, 9 hours, and 24 hours.

Results: The inhibitory effects of plasma at air volume 14 with prolonged exposure time of three hours was 20%, 64% at six hours, 82.3% at nine hours, and 100% after 24 hours exposure. With air volume of 18, the inhibitory effects upon plasma exposure were 36% for three hours, and 100% from 24 hours. Greater air volume resulted in greater inhibition of tuberculosis bacterial growth. In particular, the maximum inhibitory effect (100%) was shown in air volume of 22 (150 m3/h) after three hours of plasma exposure.

Conclusions: The results showed the correlating inhibitory effects of plasma on the growth of MTB in combination with increasing plasma exposure time and air volume.
KEYWORD
Mycobacterium tuberculosis, plasma, Non-thermal dielectric barrier discharge