A Study on the Drinking Water Treatment by Precoat Filtration and Activated Carbon Adsorption Process
Shin Dae-Yewn

Ji Sung-Nam
Kim Ji-Yeoul
Abstract
I performed the research about the drinking water treatment by precoat filtration and activated carbon adsorption process in the D water treatment plant at Gwangju. D water treatment plant inlet water is supplied from Juam lake in Jeollanamdo.
The results are as follows;
1. Element disk used in this experiment are R(pore size 10 §­), B(pore size 20 §­). And diatomaceous earth are A(cake pore size 3.5 §­), B(cake pore size 7 §­) and C(cake pore size 17 §­)
2. Filtrate of precoat filter during 30 min are B-C 10.2 > BB 5.7 > R-A 5.4 (§©/§³).
3. The water quality through B-C+AC and R-A+AC are DOC 1.76 mg/l, 1.288 mg/l respectively.
4. Total THMs produced by chlorination are 84.2 §¶/l (B-C+AC), 66.11 §¶/l (R-A+AC), 97 §¶/l (rapid sand filtration water) respectively.
5. The R-A+AC and B-C+AC process can be substitute of CWTS.