Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1156220080340020148
Journal of Environmental Health Sciences
2008 Volume.34 No. 2 p.148 ~ p.152
Simultaneous NO©ü and RSP Measurements Using Filtration Method
Yang Won-Ho

Im Seul-Gi
Kim Moon-Hyeon
Abstract
Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide (NO©ü) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for NO©ü, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 §¢), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the NO©ü and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 §¬ on a spectrophotometer. The collection efficiency(%) of NO©ü by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was 89¡¾3% and the correlation coefficient between the true NO©ü concentration and that determined by the TEA soaked filters was 0.993(p£¼0.001).
KEYWORD
nitrogen dioxide, respirable suspended particle, filter method
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)