Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1156220100360010044
Journal of Environmental Health Sciences
2010 Volume.36 No. 1 p.44 ~ p.51
Determination of 8-iso-PGF2¥á as Oxidative Stress Marker in Human Urine by High Performance Liquid Chromatography with Tandem Mass Spectrometry
Kho Young-Lim

Lee Eun-Hee
Chae Hong-Jae
Choi Kyung-Ho
Pack Do-Myung
Abstract
This study aimed to develop analytical method for 8-isoprostanes as biomarkers for oxidative stress with LC/MS/MS technique and to apply the method for human urine samples. Analyzed compounds for urinary oxidative stress markers were 7 stereo-isomers of prostaglandins and the internal standard (iso-PGF2¥á-d©þ) was used to adjust the recovery rate. The method for determining urinary iso-PGF2¥á consisted of solid phase extraction and LC/MS/MS detection. Separation of isomers of prostaglandins completed by porous graphitic carbon column and buffer solution. Detection limits for urinary markers of oxidative stress, iso-PGF2¥á with LC/MS/MS were 0.01 ng/§¢ by S/N ratio 3 and 0.028 ng/§¢ by calculated as to FDA method. The recovery (92.8~101.9%) and precision (8.8~20.7%) of analysis were feasible for detecting iso-PGF2¥á in real human urine samples. We detected 4 isomers of prostaglandins in human urine samples. Mean (standard deviation) of urinary iso-PGF2¥á concentration were 0.231 (0.117) ng/mg creatinine for smoking group and 0.154 (0.082) ng/§· creatinine for non-smoking group.
KEYWORD
oxidative stress, 8-iso-PGF2¥á, prostaglandin, LC/MS/MS
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)