KMID : 0356920090560030334
|
|
Korean Journal of Anesthesiology 2009 Volume.56 No. 3 p.334 ~ p.336
|
|
Bladder puncture associated with caudal block in a pediatric patient undergoing day surgery - A case report -
|
|
Shin Seo-Kyung
Kil Hae-Keum Lee Hye-Young Hong Jeong-Yeon
|
|
Abstract
|
|
|
Although single-shot caudal blockade is known as a relatively safe procedure, it is not always without complications. We present a case of accidental bladder puncture that was identified with fluoroscopy by chance after single-shot caudal blockade in a 17-months-old, 12 kg boy who underwent inguinal hernioplasty.
|
|
KEYWORD
|
|
Bladder puncture, Caudal block, Children
|
|
FullTexts / Linksout information
|
|
|
|