KMID : 0356920160690010027
|
|
Korean Journal of Anesthesiology 2016 Volume.69 No. 1 p.27 ~ p.31
|
|
The effect of Valsalva maneuver in attenuating skin puncture pain during spinal anesthesia: a randomized controlled trial
|
|
:Sanjay Kumar
:Sujeet Kumar Singh Gautam/:Devendra Gupta/:Anil Agarwal/:Sanjay Dhirraj/:Sandeep Khuba
|
|
Abstract
|
|
|
Background : Valsalva maneuver reduces pain by activating sinoaortic baroreceptor reflex arc. We planned this study to evaluate the role of valsalva in attenuating spinal needle-puncture pain.
Methods : Ninety American Society of Anesthesiologists (ASA) grade I and II enrolled patients undergoing elective surgery were randomized into 3 groups of 30 each. Group I (Control): didn¡¯t blow; group II (Distraction): patients blew into rubber tube; Group III (Valsalva): blew into sphygmomanometer tube and raise mercury column up to 30 mmHg for at least 20 seconds. During above procedures, spinal puncture was performed with 25-gauge spinal needle.
Results : Eighty-two patient data were analyzed. Incidence of spinal puncture pain was reduced to 10% (3 of 27) in Valsalva group as compared to 100% (28 of 28 in control group and 27 of 27 in Distraction group) observed in other two groups (P < 0.05). Severity of lumbar puncture pain as assessed by visual analog scale (0?10; where 0 is no pain and 10 is the worst imaginable pain) presented as Median (Interquartile range) were significantly reduced in the Valsalva group (0.0 [0.0] as compared to other 2 groups 2.0 [0.0] in the Distraction group and 3.0 [0.8] in Control group) (P < 0.05). Regarding time taken by CSF to fill spinal needle hub, there was no difference among the three groups (P > 0.05). None patient of all groups had post dural puncture headache (P > 0.05).
Conclusions : Valsalva can be performed routinely in ASA I and II patients undergoing spinal anesthesia as it is safe, painless and non-pharmacological method of pain attenuation.
|
|
KEYWORD
|
|
Distraction, Lumbar puncture pain, Spinal anesthesia, Valsalva maneuver, Visual analog scale
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|