KMID : 0361620110460020114
|
|
Journal of the Korean Orthopaedic Association 2011 Volume.46 No. 2 p.114 ~ p.121
|
|
Outcome of Isolated Tibial Polyethylene Insert Exchange after Total Knee Arthroplasty
|
|
Chun Churl-Hong
Kim Jeong-Woo Kweon Seok-Hyen Choi Byong-San Chun Keun-Churl
|
|
Abstract
|
|
|
Purpose: We investigated the short term outcomes of isolated tibial polyethylene insert exchange after revision total knee arthroplasty.
Materials and Methods : We selected 18 cases from 17 patients among the 20 cases from 19 patients who took isolated tibial polyethylene insert exchange after mean 69 months-follow up of TKA, which was carried out from June 1991 to August 2003. Two cases were excluded on account of loss to follow-up. In all cases, isolated tibial polyethylene insert exchange was carried out from May 1998 to October 2008 in our institute and the mean follow-up period after operation was 48 (22-142) months. We evaluated the following clinical and radiologic aspects: range of motion, HSS score, average labor time, and BMI. Together, these factors were used in clinical evaluation while femorotibial angle and radiolucent line were used in radiologic evaluation.
Results: The average range of motion was 110.6 degrees and HSS score was 86.9 in follow up period. The average femorotibial angle was valgus 5.3¡Æ. The average labor time was 9.7 hours and BMI was 25.9. Although radiolucent line was found in 4 cases, there were all confirmed to be non progressive lesion less than 2 mm. Survival rate was 100% in Kaplan-Meier survival analysis.
Conclusion: Selective isolated tibial polyethylene insert exchange can be the successful method for revision TKA in limited cases.
|
|
KEYWORD
|
|
revision total knee arthroplasty, polyethylene insert exchange
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|