KMID : 0387720220330030182
|
|
Korean Journal of Blood Transfusion 2022 Volume.33 No. 3 p.182 ~ p.194
|
|
Is Leukoreduction Needed for Plasma Products?
|
|
Youk Hee-Jeong
Chung You-Sun Kim Hyung-Suk Ko Dae-Hyun
|
|
Abstract
|
|
|
Leukoreduction is a process in which the white blood cells (WBCs) in cellular products are intentionally reduced to bring down the risk of adverse transfusion reactions, such as febrile nonhemolytic transfusion reactions or human leukocyte antigen alloimmunization. So far, Korea has not considered leukoreduction of plasma products. However there have been recommendations for leukoreduction to improve patient outcomes. The authors have experience in measuring WBCs and WBC fragment counts in plasma products and have shown that the WBC and their fragments could be efficiently removed using leukoreduction filters. Hence, it may be beneficial to begin discussions on the necessity of using leukoreduction of plasma products.
|
|
KEYWORD
|
|
Plasma, White blood cell, Leukoreduction
|
|