KMID : 0858320080110010041
|
|
Journal of the Korean Shoulder Elbow Society 2008 Volume.11 No. 1 p.41 ~ p.45
|
|
3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures
|
|
Lee Churl-Woo
Kim Hee-Chun Roh Jae-Young Park Young-Soo
|
|
Abstract
|
|
|
Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures.
Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system.
Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case.
Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.
|
|
KEYWORD
|
|
Distal clavicle, Unstable fracture, T-plate, LCP
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|