Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1004520200360020061
Journal of Dental Rehabilitation and Applied Science
2020 Volume.36 No. 2 p.61 ~ p.69
Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance
Park Gi-Beom

Shin Soo-Yeon
Abstract
Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and
Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN.

Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05).

Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.
KEYWORD
zirconia, fixed partial denture, fracture resistance, inter-abutment distance
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)