KMID : 1038920220210020079
|
|
Annals of Optometry and Contact Lens 2022 Volume.21 No. 2 p.79 ~ p.82
|
|
Intraocular Lens Scleral Fixation by Flanged Fixation Using 5-0 Polyprophylene
|
|
Choi Soo-Young
Kim Nam-Yeong Kwon Yoon-Hyung
|
|
Abstract
|
|
|
Purpose: In patient with intraocular lens dislocation, surgery was performed to fix the existing intraocular lens to the sclera by flanged fixation using 5-0 polypropylene without replacing the existing intraocular lens, and this is to be introduced.
Case summary: One mm incisions were made in the cornea at 11 and 2 o'clock and the prolapsed vitreous was removed.
Through the incised cornea, the 5-0 polypropylene is inserted through one hole of the intraocular lens and drawn out of the eye, and the other end of the 5-0 polypropylene is also drawn out of the eye through the vitreous. The ends of the 5-0 polypropylene were melted with a Low-Temperature Cautery to form a flanged shape and fixed to the sclera. No significant complications occurred after the operation.
Conclusions: It can be seen that the flanged type of scleral fixation using 5-0 polypropylene is a useful alternative to the conventional classic scleral fixation.
|
|
KEYWORD
|
|
Flanged fixation, Intraocular lens dislocation, Polypropylenes, Scleral fixation
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|