Jejunal Migration of the Stent-Graft Used for Common Hepatic Artery Pseudoaneurysm
Kim Ji-Won

Lee Byung-Hee
Abstract
Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.
KEYWORD
Foreign-Body Migration, Hepatic Artery, Stent, Aneurysm, False